Automotive components such as gears and shafts transmit power, support mechanical loads, and ensure reliable vehicle operation. Their manufacturing requires controlled heat treatment to achieve the required hardness, wear resistance, and dimensional stability. High-pressure vacuum gas quenching furnaces provide precise temperature control and rapid gas cooling, helping meet these requirements while reducing oxidation and surface contamination during heat treatment.

SIMUWU’s vacuum gas quenching technology combines vacuum and gas-cooling techniques. The process involves heat-treating metal materials in a vacuum environment, followed by rapid cooling through the injection of an inert gas (typically nitrogen or argon). The vacuum environment effectively prevents surface oxidation, while rapid cooling facilitates the formation of a uniform microstructure, thereby enhancing properties such as strength, hardness, wear resistance, and corrosion resistance.

The following are the specific technical specifications for SIMUWU’s RVGQ-669 (10 Bar):
| Furnace Type | Horizontal type, single chamber, internal recycle |
| Application process | Vacuum gas quenching |
| Loading method | Front loading |
| Max. Loading size | 600×600×900(W×H×L mm) |
| Max. Loading weight | 500kg |
| Power supply | 3 Phase, 380V(±5%); 50Hz |
| Installed power | 280kw |
| Heating power | 240kw |
| Water-cooling motor power | 200kw |
| Max design temp. | 1350℃ |
| Max.Working temp. | 1300℃ |
| Temperature uniformity (Vacuum, empty furnace, 500-1000℃) | 9 points temp testing ±5℃ |
| Temperature controller accuracy | S Type thermocouple ±1℃ |
| Quantity of heating zones | 1-Zone independent temperature control |
| Heating element | Molybdenum-lanthanum alloy |
| Empty furnace heating rate | 0~20℃ /min(speed adjustable) |
| Ultimate vacuum | 6.7 x 10-4pa (cold empty furnace condition, after fully drying the furnace) |
| Working vacuum | 6.7 x 10-3pa (empty furnace, room temperature) |
| Time to working vacuum | ≤ 45 min(After preheating the diffusion pump, cold empty furnace condition) |
| Pressure rising rate | ≤ 0.67 Pa/h (cold empty furnace condition) |
| Cooling method | Gas cooling/ Natural cooling |
| Cooling air | Nitrogen/ Argon (purity: 99.99% or 99.999%) |
| Cooling rate (empty furnace 1200℃~150℃) | ≤ 6 min |
| Max charging pressure(absolute pressure) | < 10 bar |
| Temperature control mode | Intelligent Programmable Temperature Controller |
| Operate method | Manual or automatic control |
| Equipment color | Customized |

Should you have any technical questions or requests, please feel free to contact us at any time; we are dedicated to serving you.